From: A study of balloon type, system constraint and artery constitutive model used in finite element simulation of stent deployment
Material
ρ(kg/mm 3 )
C 10
k 1
k 2
κ
D
Intima
1.07E-6
2.3E-2
25
1200
0.308
8.95E-7
Media
1.4E-3
0.18
100
0.314
5.31E-6
Adventitia
8.32E-3
4
1000
0.312
4.67E-6